Correct the time interval between logged data rows to the expected
value of 100 milliseconds by naming a new loop counter variable
to be distinct from loop counters for inner loops that
inadvertently change the outer loop operation.
This suggested patch is 1 of 3 for Ticket #2144 "libavfilter ebur128
loudness inaccuracy, irregular time interval, LFE interference".
This suggested patch supersedes the contribution of January 15, 2013
in the thread “[PATCH] lavfi: EBU R.128 irreg time, ch weights, skip
LFE” which combined multiple fixes in one patch.
Reviewed-by: Clément Bœsch <ubitux@gmail.com>
Signed-off-by: Michael Niedermayer <michaelni@gmx.at>